Electrolyte Glove Box
Solve
several problems of electrolyte glove box
1.
Our current glove box moisture sensor has strong corrosion resistance, which
solves the commonly used water analyzer. After a period of use, the measurement
is not accurate. It needs to be sent to the glove box manufacturer for
calibration, which is troublesome;
2.
Our oxygen analyzer is a Lite-On sensor, which is resistant to strong acids. It
will solve the inaccurate measurement method and the oxygen sensor will fail
when it is exposed to air after the glove box is closed for a long time.
3.
The bypass switch valve is a stainless steel valve, and it will not encounter
the situation where the sealing rubber ring in the bypass valve is corroded and
cannot be completely closed, and the bypass fails.
4.
The connection between the large pneumatic valve on the purification column and
the purification column is stainless steel, and it will not encounter the
problem of cracking in the aluminum connection.
5.
The clamps on the circulation system and the purification column are made of
strong acid-resistant stainless steel, which can not be used after cracking the
aluminum clamps after 1-2 years.
6.
Effectively solve the problem that the exhaust solenoid valve of the
purification column on the regeneration gas pipeline is often clogged (the
steam condenses inside it, resulting in the inability to open the air for the
next regeneration). The simple solenoid valve is removed and cleaned, and the
solenoid valve is conveniently located.
7.
The check valve installed on the regeneration gas pipeline is installed
scientifically, and the exhaust condensate inside can be completely eliminated
without causing the check valve to fail.
8.
The organic solvent adsorption column is acid-resistant, and it is easy to
install the acid-absorbing material. It is placed outside the control box;
there is a filter to protect the activated carbon dust from being sucked into
the purification column and the glove box. The filter aperture is 3 microns.
9.
The organic solvent adsorption column will not contact the air after replacing
the activated carbon, and has the function of adding nitrogen. Vent through the
connection port (with the glove box) so that the air inside can be replaced;
10.
There is patent for leak prevention of glove box pipeline.
11.
The glass film of the glove box is resistant to the corrosion of vapors
(carbonate, carboxylic acid esters) emitted by HF and solvents in the glove
box;
12.
The vacuum pump is equipped with an air inlet filter to prevent excessive
material dust from entering the vacuum pump;