  Today I brought you 10 tips on oral health and tooth care, hoping to help everyone’s oral health. 1. Brush your teeth with warm water every morning and evening. Brushing your teeth before going to bed is more important than brushing your teeth in the morning. In addition, rinse your mouth with clean water after three meals a day. When rinsing, use the force of water to remove food residues between your teeth as much as possible. 2. Learn to use dental floss. Brushing can only clean 70% of the teeth, and the other 30% are the gaps between the teeth. Many oral diseases are caused by the unclean gaps between the teeth. Dental floss effectively removes residual food, soft tartar, and can also clean dental plaque. Therefore, dental floss is of great significance to oral cleaning. Use of floss stick Use of dental floss rolls 3. Go to a professional dental medical institution to clean your teeth once every six months. Plaque and calculus on the tooth surface are the main culprit

Common Faults and Solutions for Glove Boxes

  1. The circulating fan cannot be started, and the glove box cannot be circulated.      cause of issue:       a. The outlet pressure of the cylinder pressure reducing valve is too low to open the angle valve;        b. The angle valve sensor switch is not sensed, and there is no feedback signal;       c. The solenoid valve that opens the angle valve is faulty, and no air pressure enters the angle valve.      Solution:       a. Check whether the cylinder gas is turned on and whether the working gas inlet pressure reaches 0.5-0.6MPa;       b. Check whether the angle valve sensor switch normally senses the open position and whether the sensor indicator light is on.     2. The water and oxygen index rises and cannot reach the value below the required value.       cause of issue:       a. Damage to the oxygen battery, battery quality problems and transmitter failure;       b. If the glove box adsorption material is used for a long time and there are many organic so

Application of Leybold Vacuum Pump SV100B in Steelmaking

  Leybold vacuum pump SV100B focuses on steelmaking in the steel industry, providing it with a series of vacuum applications and speeding up production. Few materials can affect world economic development like steel. It plays an important role not only in industry, but also in our daily lives. Steel is used in the manufacture of machines, factories, bridges, buildings, ships, automobiles and household appliances. The economic growth of emerging markets makes it the most important metal material in the 21st century. Leybold vacuum pump SV100B steelmaking under vacuum Steel is defined as an iron-carbon alloy containing less than 2% carbon, and it can additionally contain other alloying elements. Therefore, there are a series of different types of steel: structural steel, tempered steel, stainless steel, heat-resistant steel and cold-resistant steel, etc. These are just a few examples. Although the uses and properties are different, all steel grades contain iron and varying amo

Chlorine Dioxide H2O Treatment Method: How to Check Dependably

  The quantity of Americans in contact with harmful water is shocking. In reality, research has shown that more than 60 million Americans have come across toxified drinking water in the past 10 years. Aspects including farm air pollution, deteriorating plumbing, and commercial waste materials are going to pin the blame on. Unsafe water has been found throughout the usa. Just about the most notorious examples will be the water problems in Flint, Michigan. Just about the most great ways to deal with this high incidence is using chlorine dioxide treatment options. Keep reading to find out the advantages of chlorine dioxide drinking water remedies. Investigate its uses and find out how to monitor chlorine dioxide ranges. What Exactly Is Chlorine Dioxide? Simply put, chlorine dioxide is actually a petrol that is frequently used to disinfect drinking water. The water’s sanitation occurs because chlorine dioxide is definitely an oxidizing professional. It can be utilized to disinf

Common Problems and Solutions for Glove Boxes

  1. The buttons on the touch screen do not respond, and no new page pops up when pressed. The cause of the problem: the user forgot to log in or the glove box did not log in from the beginning after the power failure. Solution: In the user management interface, just log in from the beginning. 2. The vacuum pump stops working and cannot be opened from the beginning. The cause of the fault: The instantaneous current is too large when the vacuum pump is started, and the air switch is tripped and disconnected. Solution: First, check whether the power button on the vacuum pump is in the open position. Secondly, open the electrical cabinet to check whether the QF2 circuit breaker is in the open position. 3. Gas consumption in the glove box is too fast. Cause of the problem: This situation may be caused by air leakage from the cylinder pressure reducing valve, damage to the tank vacuum solenoid valve and failure to close normally, open angle valve battery valve and three-way